Potentiometer Input Alarm
Potentiometer Input Transmitter
|
Hot-Swappable Plug-In Design
Looptracker LED
Push to Test
Lifetime Warranty
|
|
Model
|
Input
|
Output Ranges
|
Features
|
Data & Applications
|
Photo
|
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V,
0-5 V,
1-5 V,
0-10 V
±5 V,
±10 V
0-1 mA,
0-20 mA,
4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC, 48-300 VDC Power
API 20xx DD for 9-30 VDC,
10-32 VAC Power (+$60) |
Data Sheet
Reference Info
Alarm Terminology
Deadband
RFI / EMI
Relay Protection & EMI Suppression
Application Examples
Milling Machine Automation
Controlling Damper Position
Fail Safe Valve Control
Manual Burner Control |
|
API 1800 G
Potentiometer Input Single Alarm Trip
Specify Input, Alarm Type & Power
API 1820 G
Potentiometer Input Dual Alarm Trip
Specify Input, Alarm Type & Power
|
Factory Configured
100 Ω to
1 MegaΩ
|
1 or 2 Field
Adjustable
7A SPDT
Alarm Relays
|
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input
Alarm Status LEDs
Push to Test/Reset
Uses 11-Pin Socket
|
Data Sheet
Reference Info
Alarm Terminology
Deadband
Relay Protection & EMI Suppression
RFI / EMI
|

|
API 4003 G
Non-Isolated Potentiometer to DC Transmitter
Specify Input, Output & Power
API 4003 G I
Isolated Potentiometer to DC Transmitter
Specify Input, Output & Power
|
Factory Configured
100 Ω to
1 MegaΩ
|
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-20mA
4-20mA
|
Hot-Swappable Plug-In Design
Looptracker® LEDs for Input and Output
Full Isolation
Push to Test
Uses 8-Pin Socket
|
Data Sheet
Applications
Milling Machine Automation
Controlling Damper Position
Fail Safe Valve Control
Reference Info
RFI / EMI
|


|
API 4008 G
Field Selectable
Isolated Potentiometer to DC Transmitter
Specify Input & Power
|
Any Full-Range
100 Ω to
1 MegaΩ
Potentiometer
|
18 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
|
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracke® LEDs for Input and Output
Full Isolation
Push to Test
Includes 8-Pin Socket
|
Data Sheet
Applications
Milling Machine Automation
Reference Info
RFI / EMI
|


|
| APD 4008
Field Selectable Minuteman Setup
Isolated Potentiometer to DC Transmitter
| Any Potentiometer
0-100 O to
0-1 Mega Ω
0 to 90% Offset Capable
Can Use Partial Potentiometer Ranges
| 18 Field Configurable Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
| Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power
|
Data Sheet
Reference Info
Alarm Terminology
Deadband
RFI / EMI
Relay Protection & EMI Suppression
Application Examples
Milling Machine Automation
Controlling Damper Position
Fail Safe Valve Control
Manual Burner Control |

|
|
|
|
|
|
|
|