The
unique circuitry of our 750 Series II Conductivity Monitor/controllers
guarantees accurate and reliable measurements. Drift-free
performance is assured by "field proven" electronics,
including automatic DC offset compensation and highly accurate
drive voltage.
Since Temperature Compensation is at the heart
of accurate water measurement, all Myron L Monitor/controllers
feature a highly refined and precise TC circuit. This feature
perfectly matches the water temperature coefficient as it
changes. All models are corrected to 25°C. The TC may
be disabled to conform with USP requirements.
Built-in electronic calibration allows for fast
quality checks.
A push-to-test button makes setpoint checks
easy, while the internal alarm set discourages unauthorized
adjustments.
Standard on all controller models is a heavy-duty,
10-amp output relay, operating on either increasing or decreasing
readings. Bright green/red LEDs indicate readings above or
below setpoint.
Digital and Analog 750 Series II models have
an IP65/NEMA 4X water-resistant & corrosion-proof rated
enclosure. At 152 x 122 mm/6 x 4.8 in., all models are suitable
for panel, bench or surface mounting.
Additional options include a 3 Sensor Input
Switch and/or a 3 Range Switch and a Remote Alarm model
RA.
Sensor
- CS51LC, CS51 and CS52
These
reliable sensors feature an integral temperature sensor to
ensure accurate and rapid automatic temperature compensation.
The sturdy polypropylene bushing is modular for easy inexpensive
replacement. Several alternatives for the metal portion of
the sensor are available, depending on the demands of the
application.
CS51LC sensors (0.1 constant) are used for 5
and below.
CS51 sensors (1.0 constant) are used between
0-10 and 0-20,000.
CS52 sensors (10.0 constant) are used above
20,000.
Low cost, low temperature, low pressure sensors
available upon request. See 750II Sensor Selection Guide.
Applications
- Reverse Osmosis
- Process Control
- Seawater Desalination
- Waste Treatment
- Food Processing
- Plating
- Power Plants
- Laboratories
- Printing
- Aquaculture
- Agriculture
- Environmental Studies
- Medical
- Boilers (250 psi @ 205°C)
- Cooling Towers
Features
- 34 Conductivity/TDS ranges: 0- 1 microsiemens/ppm to
0-200millisiemens/ppt
- Choice of 3½ digit display or analog meter
- Automatic temperature compensation to 25°C
- Isolated 0-10 VDC Recorder Output standard
- IP65/NEMA 4X water resistant and corrosion proof enclosure
- Built-in electronic calibration
- Single set point/alarm standard
- Adjustable setpoint hysteresis
- Solid State 24 VDC Output
- 10 amp relay operates on choice of increasing or decreasing
reading
- LEDs show "above/below" Alarm/control status
- Push-to-test set point check
- Internal set point discourages unauthorized adjustment
- Selectable 115/230 VAC
- CE Certified
- Reliable, easily installed sensors
Sensor
Specifications
- Temperature Compensation: Integral thermistors provide
automatic TC to 25ºC between 0-100ºC/32-212ºF.
- Pressure /Temperature Limits: CS51: 100 psi / 690 kPa
@ 100°C/212°F. 250 psig @ 205°C, Models CS40
and CS41 sensors available on special order.
- Bushing: Modular Polypropylene threaded 3/4 NPT.
1/2 PVDF or 316 stainless steel fittings available
as option.
- Cable: Shielded 10 ft./3 meters standard 25 and 100
ft./ 8 and 30 meter lengths available. 100 ft./30 meter
is maximum recommended.
- Dimensions: CS51: Metal portion 30 L x 13 Dia. mm/ 1.2
L x .5 Dia. in.
|
750 Series
II
Data Sheet
(includes specs, options and order info)
|
click here: PDF
|
|
750II Sensor Selection Guide
|
click here:
PDF
|
| 750II
Range Selection Guide |
click
here: PDF |
| Conductivity
Sensor - CSA Series |
click
here: PDF |
| Conductivity/Resistivity
Sensor #CS40 |
click
here: PDF |
| Conductivity/Resistivity
Sensor #CS41 |
click
here: PDF |
| Conductivity
Sensor #CS50 & 60 |
click
here: PDF |
| Conductivity
Sensor #CS51 |
click
here: PDF |
| Conductivity
Sensor #CS52 |
click
here: PDF |
| Sanitec
Fitting Sensor Option |
click
here: PDF |
|
Operation Manual
|
click here:
PDF
|
|