Process Control Home
 
Alpha Controls
 

Low Pressure Differential Data Logger SmartReader Plus 4

SmartReader Plus 4 (LPD)
The ACR Low Pressure Differential SmartReader Plus 4 data logger is designed to be used in applications where precise and very low differential pressure measurements are required.


Low Pressure Differential Data Logger
SmartReader Plus 4 (LPD) 

Type:

Silicone piezoresistive strain gauge

Range:

+/-0.5"W, +/-1.0"W, +/-2.0"W, +/-5.0"W, +/-10"W

Resolution:

< 0.01" WC

Memory Size:

32 KB

No. of Channels:

Two. (One for the internal compensating temperature thermistor and one for the pressure sensor)

Maximum Pressure:

+/-40" WC

Media:

Non-corrosive gases and dry air

Hysteresis And Repeatability:

+/- 0.05% FS (typical)

Long Term Stability:

+/-0.5% FS

Operating:

-40 to 70 C (-40 to 158 F)

Compensated:

0 to 70 C (32 to 158 F)

Calibrated:

+/-0.5, +/-1, & +/-2" 0.05" W.C. +/-5 & +/-10" 0.1" W.C

Thermal:

+/-0.5% FS
(over-compensated range)

Non-linearity:

+/-0.05% FS
(best fit straight line)

PDF

Low,Pressure,Differential,Data,Logger,SmartReader,Plus 4

Size: 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: NorylŪ Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use). Factory replaceable
Memory Size: 32 K (21,500 readings). 128 K (87,000 readings). 1.5 MB (1,000,000 readings). See specific models for availability
Sampling Method: 1. Continuous (First-in, First-out); not available with sample rates faster than 8 seconds.) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates from 25 per second to one reading every 8 hours. (BP-101 battery pack or PS-201 Power Supply required for sample rates faster than 8 seconds. See Accessories section for details)
Resolution: 12 bit (1 part in 4096)
PC Requirements: IBM PC or 100% compatible running MSŪ Windows 3.1,95,98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/ Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"


Powerful Solutions for Instrumentation & Control Problems!
Low Pressure Differential Data Logger SmartReader Plus 4

Site Designed By Panther Marketing